RatingPlate Find your size
Browse the site

Type guides, state costs, model specs, and brand pages.

Heater Types

Heat Pump Water HeatersHigh-efficiency electric replacements and hybrid tanks.Condensing Tankless Water HeatersCondensing whole-home flow with venting constraints.Gas Tank Water HeatersStraight swaps when gas storage is still the fit.

Plan Your Swap

Sizing guideCapacity, first-hour rating, and temperature-rise fit.Accessories hubInstall extras, code-adjacent parts, and paid-link accessory picks.Upgrade from NHP50Replacement candidates and projected operating-cost delta.Upgrade from NHP65Replacement candidates and projected operating-cost delta.Upgrade from NHP80Replacement candidates and projected operating-cost delta.Upgrade from NPE 210S2Replacement candidates and projected operating-cost delta.Upgrade from PROE50 T2 RH95Replacement candidates and projected operating-cost delta.HPTA 50 2 vs HPTA 80 2Side-by-side specs, efficiency, and fit differences.HPTS 50 2 vs NHP50Side-by-side specs, efficiency, and fit differences.NHP120 vs PROPH80 T2 RH400 30Side-by-side specs, efficiency, and fit differences.NPE 210S2 vs NPE 240S2Side-by-side specs, efficiency, and fit differences.

Guides & Data

California heat pump guideLocal rates, rebates, and operating costs.Colorado heat pump guideLocal rates, rebates, and operating costs.Massachusetts heat pump guideLocal rates, rebates, and operating costs.Oregon heat pump guideLocal rates, rebates, and operating costs.Washington heat pump guideLocal rates, rebates, and operating costs.DOE 2029 standardsWhat changes in 2029 and which product classes move first.

Brands

A.O. Smith Water HeatersPublished models, product lines, and brand coverage.Bradford White Water HeatersPublished models, product lines, and brand coverage.Navien Water HeatersPublished models, product lines, and brand coverage.Noritz Water HeatersPublished models, product lines, and brand coverage.Rheem Water HeatersPublished models, product lines, and brand coverage.Rinnai Water HeatersPublished models, product lines, and brand coverage.Takagi Water HeatersPublished models, product lines, and brand coverage.
Model specs

NHP80

Noritz / 74-Gallon Heat Pump Water Heater
Lower running cost than standard electric, but height, 240V, and condensate still decide fit.
UEF3.48Certified efficiency
First hour86 galHot water delivery
Footprint74" × 28"Height × depth
Running cost~$245/yrU.S. average electricity
Estimated annual savings: $683 compared to a standard standard electric tank. Based on U.S. average energy prices. See all heat pump models

NHP80 operating cost

This unit saves roughly $683 every year compared to the standard electric tank it replaces
NHP80
$245/yr
Std tank (0.92 UEF)
$929/yr
~1.8year payback
At $683/yr in savings, the upfront premium pays for itself in about 1.8 years. Over 10 years: roughly $5,630 in net savings.
Your state changes the math. Annual cost ranges from ~$157/yr (ND) to ~$593/yr (HI).
U.S. avg electricity: $0.17/kWh (EIA, Dec 2025). The federal tax credit of up to $2,000 under IRA Section 25C expired December 31, 2025. State and utility rebates may still apply.
NHP80 in the 80-gallon heat pump class: #8 of 9 on efficiency.

Should this be on your shortlist?

Best for

10-year tank warranty (class-leading)

Not ideal for

lower efficiency than most class peers, deepest footprint in class

  • Why it makes shortlists: solid mid-class efficiency (#8 of 9)
The bill may work. Now check what actually changes on install day before you let the shortlist settle.

Switching to the NHP80

From a standard electric tank

Same voltage (240V). Verify breaker size matches unit requirements (30A typical).
Taller unit (74"). Measure overhead clearance.
Condensate drain needed. Floor drain or condensate pump.
Air space needed around the unit for heat exchange.
Fewest install changes of any upgrade path. Scope depends on existing wiring, clearances, and condensate routing.

From a gas tank

New 240V/30A circuit required. Hire an electrician.
Gas line capped. No more gas bill for hot water.
Existing flue/vent can be removed.
Condensate drain needed.
Two trades needed (plumber + electrician).

From an older heat pump

Same electrical. Same condensate drain.
Check height. This unit is 74" tall.
Standard water connections.
Similar installation profile. Verify dimensions, clearances, and condensate routing match your existing setup.
Height, electrical service, condensate, and noise. These are the four things that determine whether a heat pump fits your space and your quote.

NHP80 installation specifications

Dimensions

Height74 in
Width28 in
Depth28 in
Connections3/4 inch NPT

Electrical

Voltage240V
Amperage23A
Breaker30A dedicated

Heat Pump

Min ambient temp35°F
RefrigerantR-134a
Noise54 dBA

Common install considerations for heat pump units

What is required depends on your existing installation, local code, and installer preference.

Thermal Expansion Tank Often required by code Check on Amazon (paid link)
Water Heater Drain Pan Often required by code Check on Amazon (paid link)
Earthquake Straps (Seismic Restraints) Often required by code Check on Amazon (paid link)
Full accessories list

Warranty

Coverage

Tank10 yr
Parts10 yr
Labor1 yr
Class rankings: 80-gallon heat pump water heaters

Rankings

Efficiency (UEF) higher is better
#8of 9Efficiency
1
Rheem PROPH80 T2 RH4...
4.07
2
Navien NWP500S080AUMB
4.05
3
Bradford White RE2HP...
4
4
Rinnai REHP80BM
4
5
A. O. Smith HPTA-80-2
3.88
6
A. O. Smith HPTS-80-2
3.88
7
Bradford White RE2H80T
3.59
8
Noritz NHP80
3.48
9
Noritz NHP120
3.38
Height shortest to tallest
#6of 9Compactness
1
Bradford White RE2HP...
51.1"
2
A. O. Smith HPTA-80-2
69"
3
A. O. Smith HPTS-80-2
69"
4
Bradford White RE2H80T
70.8125"
5
Navien NWP500S080AUMB
71.6"
6
Noritz NHP80
74"
7
Rheem PROPH80 T2 RH4...
74.19"
8
Rinnai REHP80BM
74.2"
9
Noritz NHP120
84.5"
First Hour Rating higher means more hot water
#8of 9Hot Water Delivery
1
Noritz NHP120
105 gal
2
A. O. Smith HPTA-80-2
95 gal
3
A. O. Smith HPTS-80-2
95 gal
4
Rinnai REHP80BM
91 gal
5
Bradford White RE2H80T
88 gal
6
Bradford White RE2HP...
88 gal
7
Rheem PROPH80 T2 RH4...
87 gal
8
Noritz NHP80
86 gal
9
Navien NWP500S080AUMB
85 gal
Starting May 2029, new federal standards require heat pump technology for electric water heaters over 35 gallons. Electric tanks 35 gal and under can still use resistance elements. Every heat pump on this list already exceeds the future standard. Read the full DOE 2029 analysis

Common questions about the Noritz NHP80

From manufacturer specs, EIA energy data, and DOE regulations.

How much does the NHP80 cost to run per year?
~$245/yr at the U.S. average electricity rate. That is roughly $683/yr less than a standard electric tank.
How much hot water does the NHP80 deliver?
86 gallons in the first hour from a 74-gallon tank. Suitable for a household of 1 to 3 people at medium draw.
Will the NHP80 fit in my space?
74" tall, 28" wide, 28" deep. Measure your space including clearances before ordering.
What electrical circuit does the NHP80 need?
240V, 30A dedicated circuit. Check your electrical panel before installation.
Does the NHP80 work in cold climates?
The heat pump operates down to 35°F ambient temperature. Below that, it switches to standard electric resistance mode, losing the efficiency advantage. In cold climates, install inside the heated building envelope, not in an unheated garage.
What warranty does the NHP80 come with?
10-year tank warranty, 10-year parts. Register with Noritz after installation to activate full coverage.
Is the NHP80 eligible for rebates?
ENERGY STAR certified heat pump water heater. The federal tax credit (IRA Section 25C, up to $2,000) expired December 31, 2025. State and utility rebates may still apply depending on your location.
Is this unit future-proof under the 2029 DOE standards?
Yes. Starting May 2029, electric water heaters over 35 gallons must use heat pump technology. This unit already exceeds that standard.
Full specifications
Performance
UEF3.48
First Hour Rating86 gal
kW Input4.5 kW
Draw PatternHigh
Est. Annual Energy1424 kWh/yr
Capacity
Storage Volume74 gal
Physical
Height74 in
Width28 in
Depth28 in
Connections3/4 inch NPT
Electrical
Voltage240 V
Amperage23 A
Breaker30A dedicated
Heat Pump
Type240 Volt Integrated HPWH
Min Ambient35 °F
RefrigerantR-134a
Sound Level54 dBA
Warranty
Tank10 yr
Parts10 yr
Labor1 yr
Certifications
ENERGY STARCertified
MarketsUnited States, Canada
Keep the route moving

Other Noritz models and the full heat pump guide, if this one isn't the right fit.

Head-to-head comparisons
Sources. ENERGY STAR, Noritz, Retailer listing. Data compiled March 2026.Methodology
As an Amazon Associate I earn from qualifying purchases. RatingPlate may earn a commission when you use qualifying Amazon links. Links to Amazon are marked "(paid link)". We never display prices because Amazon prohibits showing prices outside their platform.