Model specs
PROPH50 T2 RH400-30
Rheem / 45-Gallon Heat Pump Water Heater
Lower running cost than standard electric, but height, 240V, and condensate still decide fit.
UEF3.88Certified efficiency
First hour67 galHot water delivery
Footprint61.75" × 22.5"Height × depth
Running cost~$146/yrU.S. average electricity
Estimated annual savings: $469 compared to a standard standard electric tank. Based on U.S. average energy prices. See all heat pump models
PROPH50 T2 RH400-30 operating cost
This unit saves roughly $469 every year compared to the standard electric tank it replaces
PROPH50 T2 RH400-30
$146/yr
Std tank (0.92 UEF)
$615/yr
~2.6year payback
At $469/yr in savings, the upfront premium pays for itself in about 2.6 years. Over 10 years: roughly $3,490 in net savings.
Your state changes the math. Annual cost ranges from ~$93/yr (ND) to ~$352/yr (HI).
U.S. avg electricity: $0.17/kWh (EIA, Dec 2025). The federal tax credit of up to $2,000 under IRA Section 25C expired December 31, 2025. State and utility rebates may still apply.
PROPH50 T2 RH400-30 in the 50-gallon heat pump class: #2 of 8 on efficiency.
Should this be on your shortlist?
Best for
top-tier efficiency, 10-year tank warranty (class-leading)
- Why it makes shortlists: top-half efficiency in a 8-model class
Shortlist alternatives in 50-gallon heat pump:
Bradford White RE2HP50-1NCTTUEF 3.89 · 46.1" tallNavien NWP500S050AUMBUEF 3.85 · 63" tallA. O. Smith HPTS-50-2UEF 3.8 · 63" tallCheck price and availability: Rheem PROPH50 T2 RH400-30 on Amazon (paid link)
The bill may work. Now check what actually changes on install day before you let the shortlist settle.
Switching to the PROPH50 T2 RH400-30
From a standard electric tank
Same voltage (240V). Verify breaker size matches unit requirements (30A typical).
Taller unit (61.75"). Measure overhead clearance.
Condensate drain needed. Floor drain or condensate pump.
Air space needed around the unit for heat exchange.
Fewest install changes of any upgrade path. Scope depends on existing wiring, clearances, and condensate routing.
From a gas tank
New 240V/30A circuit required. Hire an electrician.
Gas line capped. No more gas bill for hot water.
Existing flue/vent can be removed.
Condensate drain needed.
Two trades needed (plumber + electrician).
From an older heat pump
Same electrical. Same condensate drain.
Check height. This unit is 61.75" tall.
Standard water connections.
Similar installation profile. Verify dimensions, clearances, and condensate routing match your existing setup.
Height, electrical service, condensate, and noise. These are the four things that determine whether a heat pump fits your space and your quote.
PROPH50 T2 RH400-30 installation specifications
Dimensions
Height61.75 in
Width22.25 in
Depth22.5 in
Weight185 lbs
Connections3/4 inch NPT
Electrical
Voltage240V
Amperage21A
Breaker30A dedicated
Heat Pump
Min ambient temp37°F
RefrigerantR-134a
Common install considerations for heat pump units
What is required depends on your existing installation, local code, and installer preference.
Warranty
Coverage
Tank10 yr
Parts10 yr
Class rankings: 50-gallon heat pump water heaters
Rankings
Efficiency (UEF) higher is better
#2Runner-UpEfficiency · 8 models tested
1
Bradford White RE2HP...
2
Rheem PROPH50 T2 RH4...
3
Navien NWP500S050AUMB
4
A. O. Smith HPTS-50-2
5
Rinnai REHP50BM
6
A. O. Smith HPTA-50-2
7
Noritz NHP50
8
Bradford White RE2H50S
Height shortest to tallest
#4of 8Compactness
1
Bradford White RE2HP...
2
Noritz NHP50
3
Bradford White RE2H50S
4
Rheem PROPH50 T2 RH4...
5
A. O. Smith HPTA-50-2
6
A. O. Smith HPTS-50-2
7
Navien NWP500S050AUMB
8
Rinnai REHP50BM
First Hour Rating higher means more hot water
#2Runner-UpHot Water Delivery · 8 models tested
1
Rinnai REHP50BM
2
Rheem PROPH50 T2 RH4...
3
A. O. Smith HPTA-50-2
4
A. O. Smith HPTS-50-2
5
Bradford White RE2H50S
6
Bradford White RE2HP...
7
Navien NWP500S050AUMB
8
Noritz NHP50
Starting May 2029, new federal standards require heat pump technology for electric water heaters over 35 gallons. Electric tanks 35 gal and under can still use resistance elements. Every heat pump on this list already exceeds the future standard. Read the full DOE 2029 analysis
Common questions about the Rheem PROPH50 T2 RH400-30
From manufacturer specs, EIA energy data, and DOE regulations.
How much does the PROPH50 T2 RH400-30 cost to run per year?
~$146/yr at the U.S. average electricity rate. That is roughly $469/yr less than a standard electric tank.
How much hot water does the PROPH50 T2 RH400-30 deliver?
67 gallons in the first hour from a 45-gallon tank. Suitable for a household of 1 to 3 people at medium draw.
Will the PROPH50 T2 RH400-30 fit in my space?
61.75" tall, 22.25" wide, 22.5" deep. Measure your space including clearances before ordering.
What electrical circuit does the PROPH50 T2 RH400-30 need?
240V, 30A dedicated circuit. Check your electrical panel before installation.
Does the PROPH50 T2 RH400-30 work in cold climates?
The heat pump operates down to 37°F ambient temperature. Below that, it switches to standard electric resistance mode, losing the efficiency advantage. In cold climates, install inside the heated building envelope, not in an unheated garage.
What warranty does the PROPH50 T2 RH400-30 come with?
10-year tank warranty, 10-year parts. Register with Rheem after installation to activate full coverage.
Is the PROPH50 T2 RH400-30 eligible for rebates?
ENERGY STAR certified heat pump water heater. The federal tax credit (IRA Section 25C, up to $2,000) expired December 31, 2025. State and utility rebates may still apply depending on your location.
Is this unit future-proof under the 2029 DOE standards?
Yes. Starting May 2029, electric water heaters over 35 gallons must use heat pump technology. This unit already exceeds that standard.
Full specifications
| Performance | |
| UEF | 3.88 |
|---|---|
| First Hour Rating | 67 gal |
| kW Input | 4.5 kW |
| Draw Pattern | Medium |
| Est. Annual Energy | 846 kWh/yr |
| Capacity | |
| Storage Volume | 45 gal |
| Physical | |
| Height | 61.75 in |
| Width | 22.25 in |
| Depth | 22.5 in |
| Weight | 185 lbs |
| Connections | 3/4 inch NPT |
| Electrical | |
| Voltage | 240 V |
| Amperage | 21 A |
| Breaker | 30A dedicated |
| Heat Pump | |
| Type | 240 Volt Integrated HPWH |
| Min Ambient | 37 °F |
| Refrigerant | R-134a |
| Warranty | |
| Tank | 10 yr |
| Parts | 10 yr |
| Certifications | |
| ENERGY STAR | Certified |
| Markets | United States |
Keep the route moving
Other Rheem models and the full heat pump guide, if this one isn't the right fit.
- PROE50 T2 RH95 47-gal electric tank
- PROPH40 T2 RH400-30 36-gal heat pump
- PROPH65 T2 RH400-30 59-gal heat pump
- PROPH80 T2 RH400-30 72-gal heat pump
- RTGH-95DVLN-3 9.5 GPM condensing tankless
Head-to-head comparisons
Sources. Distributor listing, ENERGY STAR, Retailer listing, Rheem. Data compiled March 2026.Methodology
As an Amazon Associate I earn from qualifying purchases. RatingPlate may earn a commission when you use qualifying Amazon links. Links to Amazon are marked "(paid link)". We never display prices because Amazon prohibits showing prices outside their platform.