Model specs
RE2HP65-1NCTT
Bradford White / 65-Gallon Heat Pump Water Heater
Lower running cost than standard electric, but height, 240V, and condensate still decide fit.
UEF4.2Certified efficiency
First hour82 galHot water delivery
Height44.6"Primary fit constraint
Running cost~$204/yrU.S. average electricity
Estimated annual savings: $726 compared to a standard standard electric tank. Based on U.S. average energy prices. See all heat pump models
RE2HP65-1NCTT operating cost
This unit saves roughly $726 every year compared to the standard electric tank it replaces
RE2HP65-1NCTT
$204/yr
Std tank (0.92 UEF)
$929/yr
~1.7year payback
At $726/yr in savings, the upfront premium pays for itself in about 1.7 years. Over 10 years: roughly $6,060 in net savings.
Your state changes the math. Annual cost ranges from ~$130/yr (ND) to ~$492/yr (HI).
U.S. avg electricity: $0.17/kWh (EIA, Dec 2025). The federal tax credit of up to $2,000 under IRA Section 25C expired December 31, 2025. State and utility rebates may still apply.
RE2HP65-1NCTT in the 65-gallon heat pump class: #1 of 8 on efficiency.
Should this be on your shortlist?
Best for
highest efficiency in class, shortest in class, 10-year tank warranty (class-leading)
Not ideal for
heaviest in class
- Why it makes shortlists: leads the class on operating cost
Shortlist alternatives in 65-gallon heat pump:
Rheem PROPH65 T2 RH400-30UEF 4.05 · 64.2" tallNavien NWP500S065AUMBUEF 4.03 · 63" tallRinnai REHP65BMUEF 3.9 · 65.5" tallThe bill may work. Now check what actually changes on install day before you let the shortlist settle.
Switching to the RE2HP65-1NCTT
From a standard electric tank
Same voltage (240V). Verify breaker size matches unit requirements (30A typical).
Taller unit (44.6"). Measure overhead clearance.
Condensate drain needed. Floor drain or condensate pump.
Air space needed around the unit for heat exchange.
Fewest install changes of any upgrade path. Scope depends on existing wiring, clearances, and condensate routing.
From a gas tank
New 240V/30A circuit required. Hire an electrician.
Gas line capped. No more gas bill for hot water.
Existing flue/vent can be removed.
Condensate drain needed.
Two trades needed (plumber + electrician).
From an older heat pump
Same electrical. Same condensate drain.
Check height. This unit is 44.6" tall.
Standard water connections.
Similar installation profile. Verify dimensions, clearances, and condensate routing match your existing setup.
Height, electrical service, condensate, and noise. These are the four things that determine whether a heat pump fits your space and your quote.
RE2HP65-1NCTT installation specifications
Dimensions
Height44.6 in
Width22 in
Weight280 lbs
Electrical
Voltage240V
Amperage19A
Heat Pump
Min ambient temp37°F
RefrigerantR-134a
Common install considerations for heat pump units
What is required depends on your existing installation, local code, and installer preference.
Warranty
Coverage
Tank10 yr
Class rankings: 65-gallon heat pump water heaters
Rankings
Efficiency (UEF) higher is better
#1Class LeaderEfficiency · 8 models tested
1
Bradford White RE2HP...
2
Rheem PROPH65 T2 RH4...
3
Navien NWP500S065AUMB
4
Rinnai REHP65BM
5
A. O. Smith HPTA-66-2
6
A. O. Smith HPTS-66-2
7
Bradford White RE2H65T
8
Noritz NHP65
Height shortest to tallest
#1Class LeaderCompactness · 8 models tested
1
Bradford White RE2HP...
2
A. O. Smith HPTA-66-2
3
A. O. Smith HPTS-66-2
4
Navien NWP500S065AUMB
5
Bradford White RE2H65T
6
Noritz NHP65
7
Rheem PROPH65 T2 RH4...
8
Rinnai REHP65BM
First Hour Rating higher means more hot water
#2Runner-UpHot Water Delivery · 8 models tested
1
A. O. Smith HPTA-66-2
2
A. O. Smith HPTS-66-2
3
Bradford White RE2HP...
4
Navien NWP500S065AUMB
5
Rinnai REHP65BM
6
Bradford White RE2H65T
7
Rheem PROPH65 T2 RH4...
8
Noritz NHP65
Starting May 2029, new federal standards require heat pump technology for electric water heaters over 35 gallons. Electric tanks 35 gal and under can still use resistance elements. Every heat pump on this list already exceeds the future standard. Read the full DOE 2029 analysis
Common questions about the Bradford White RE2HP65-1NCTT
From manufacturer specs, EIA energy data, and DOE regulations.
How much does the RE2HP65-1NCTT cost to run per year?
~$204/yr at the U.S. average electricity rate. That is roughly $726/yr less than a standard electric tank.
How much hot water does the RE2HP65-1NCTT deliver?
82 gallons in the first hour from a 65-gallon tank. Suitable for a household of 1 to 3 people at medium draw.
Will the RE2HP65-1NCTT fit in my space?
44.6" tall, 22" wide. Measure your space including clearances before ordering.
Does the RE2HP65-1NCTT work in cold climates?
The heat pump operates down to 37°F ambient temperature. Below that, it switches to standard electric resistance mode, losing the efficiency advantage. In cold climates, install inside the heated building envelope, not in an unheated garage.
What warranty does the RE2HP65-1NCTT come with?
10-year tank warranty. Register with Bradford White after installation to activate full coverage.
Is the RE2HP65-1NCTT eligible for rebates?
ENERGY STAR certified heat pump water heater. The federal tax credit (IRA Section 25C, up to $2,000) expired December 31, 2025. State and utility rebates may still apply depending on your location.
Is this unit future-proof under the 2029 DOE standards?
Yes. Starting May 2029, electric water heaters over 35 gallons must use heat pump technology. This unit already exceeds that standard.
Full specifications
| Performance | |
| UEF | 4.2 |
|---|---|
| First Hour Rating | 82 gal |
| kW Input | 4.6 kW |
| Draw Pattern | High |
| Est. Annual Energy | 1181 kWh/yr |
| Capacity | |
| Storage Volume | 65 gal |
| Physical | |
| Height | 44.6 in |
| Width | 22 in |
| Weight | 280 lbs |
| Electrical | |
| Voltage | 240 V |
| Amperage | 19 A |
| Heat Pump | |
| Type | 240 Volt Integrated HPWH |
| Min Ambient | 37 °F |
| Refrigerant | R-134a |
| Warranty | |
| Tank | 10 yr |
| Certifications | |
| ENERGY STAR | Certified |
| Markets | United States, Canada |
Keep the route moving
Other Bradford White models and the full heat pump guide, if this one isn't the right fit.
- RE2H50S 45-gal heat pump
- RE2H65T 64-gal heat pump
- RE2H80T 75-gal heat pump
- RE2HP50-1NCTT 45-gal heat pump
- RE2HP80-1NCTT 75-gal heat pump
Head-to-head comparisons
Sources. Bradford White, ENERGY STAR, Retailer listing. Data compiled March 2026.Methodology
As an Amazon Associate I earn from qualifying purchases. RatingPlate may earn a commission when you use qualifying Amazon links. Links to Amazon are marked "(paid link)". We never display prices because Amazon prohibits showing prices outside their platform.