No longer manufactured. GE Profile lists the PF80S10FPY01 as no longer being manufactured. These specs remain useful if you own one or find remaining stock; for a new purchase, compare current models.
Manufacturer page.
Estimated annual savings: $717 compared to a standard electric tank. Based on U.S. average energy prices.
See all heat pump models
PF80S10FPY01 operating cost
This unit saves roughly $717 every year compared to the standard electric tank it replaces
~1.7year payback
At $717/yr in savings, the upfront premium pays for itself in about 1.7 years. Over 10 years: roughly $5,970 in net savings.
Your state changes the math. Annual cost ranges from ~$175/yr (ND) to ~$627/yr (HI).
U.S. avg electricity: 18.0¢/kWh (EIA, 12-month avg. through Aug 2026). The federal tax credit of up to $2,000 under IRA Section 25C expired December 31, 2025. State and utility rebates may still apply.
Your state changes the cost. Ranges from $175/yr to $627/yr depending on your state's electricity rate.
PF80S10FPY01 cost by state
Ranges from $175/yr to $627/yr depending on your state's electricity rate. U.S. average: $256/yr.
Based on 1417 kWh/yr (ENERGY STAR rated) at each state's residential electricity rate (EIA, 12-month avg. through Aug 2026). Click a state for rebates, code requirements, and model rankings.
PF80S10FPY01 in the 80-gallon heat pump class: #12 of 17 on efficiency.
Should this be on your shortlist?
10-year tank warranty (class-leading)
lower efficiency than most class peers
- Why it makes shortlists: solid mid-class efficiency (#12 of 17)
Within GE Profile's 80-gallon heat pump lineup, this page fills a specific role.
Where it sits in the GE Profile lineup
- On efficiency, GE Profile PH80S10BPY01 sits higher in GE Profile's 80-gallon heat pump lineup at 4.40 UEF versus 3.50 here.
- For heavier simultaneous demand, GE Profile PH80S10BPY01 is higher at 101 first-hour gallons versus 94 here.
- Fit is strongest where height is tight: this is the shortest published option in GE Profile's 80-gallon heat pump lineup at 76.4 inches.
The bill may work. Now check what actually changes on install day before you let the shortlist settle.
Switching to the PF80S10FPY01
From a standard electric tank
✓
Same voltage (120V). Verify breaker size matches unit requirements (15A typical).
▲
Taller unit (76.375"). Measure overhead clearance.
▲
Condensate drain needed. Floor drain or condensate pump.
▲
Air space needed around the unit for heat exchange.
Fewest install changes of any upgrade path. Scope depends on existing wiring, clearances, and condensate routing.
From a gas tank
▲
New 120V/15A circuit required. Hire an electrician.
✓
Gas line capped. No more gas bill for hot water.
✓
Existing flue/vent can be removed.
▲
Condensate drain needed.
Two trades needed (plumber + electrician).
From an older heat pump
✓
Same electrical. Same condensate drain.
▲
Check height. This unit is 76.375" tall.
✓
Standard water connections.
Similar installation profile. Verify dimensions, clearances, and condensate routing match your existing setup.
Height, electrical service, condensate, and noise. These are the four things that determine whether a heat pump fits your space and your quote.
PF80S10FPY01 installation specifications
Dimensions
Height76.375 in
Width27 in
Depth27 in
Weight331 lbs
Connections3/4 inch NPT
Electrical
Voltage120V
Amperage7.5A
Breaker15A dedicated
Heat Pump
Min ambient temp35°F
RefrigerantR1234YF
Noise41 dBA
Safety and installation warnings
These warnings apply to this water heater type. Always follow the manufacturer's installation instructions and local building codes. Hire a licensed professional for installation.
T&P relief valve. Every tank-type water heater has a temperature and pressure relief (T&P) valve. This is a critical safety device that prevents tank rupture by releasing water if temperature exceeds 210°F or pressure exceeds 150 PSI. The discharge pipe must run to within 6 inches of the floor or to an exterior drain. Never cap or plug the T&P valve. Test it annually.
Scald prevention. The recommended maximum water temperature is 120°F to prevent scalding. Higher temperatures (130-140°F) reduce Legionella bacteria risk but require a thermostatic mixing valve at the outlet to deliver safe temperatures at fixtures. Some jurisdictions require mixing valves when the tank is set above 120°F.
Cold-climate performance. Below 35°F ambient air temperature, the heat pump compressor shuts off and the unit falls back to electric resistance heating at much lower efficiency. The rated UEF assumes DOE test conditions (67°F ambient, 58°F inlet water). In cold climates or unconditioned spaces (garages, unfinished basements), actual annual efficiency will be lower than the rated UEF, and energy costs will be higher than the estimates shown above.
Cold exhaust air. Heat pump water heaters extract heat from surrounding air and exhaust cold, dehumidified air. Do not install in a space that is already difficult to heat. The unit will lower the room temperature by several degrees, which may increase HVAC costs or reduce heat pump efficiency in winter.
Common install considerations for heat pump units
What is required depends on your existing installation, local code, and installer preference.
Earthquake Straps (Seismic Restraints) Often required by code Check on Amazon (paid link)
Warranty
Coverage
Tank10 yr
Parts10 yr
Labor1 yr
Class rankings: 80-gallon heat pump water heaters
Rankings
Efficiency (UEF) higher is better
#12of 17Efficiency
10
American HPA10280H04...
12
GE Profile PF80S10FP...
14
Rheem PROPH80 T0 RH1...
Height shortest to tallest
#14of 17Compactness
14
GE Profile PF80S10FP...
15
GE Profile PH80S10BP...
First Hour Rating higher means more hot water
#6of 17Hot Water Delivery
12
Bradford White RE2HP...
13
Rheem PROPH80 T2 RH4...
16
Rheem PROPH80 T0 RH1...
⚡
Starting May 2029, new federal standards require heat pump technology for electric water heaters over 35 gallons. Electric tanks 35 gal and under can still use resistance elements. Every heat pump on this list already exceeds the future standard.
Read the full DOE 2029 analysis
Common questions about the GE Profile PF80S10FPY01
From manufacturer specs, EIA energy data, and DOE regulations.
How much does the PF80S10FPY01 cost to run per year?
~$256/yr at the U.S. average electricity rate. That is roughly $717/yr less than a standard electric tank.
How much hot water does the PF80S10FPY01 deliver?
94 gallons in the first hour from a 80-gallon tank. Suitable for a household of 1 to 3 people at medium draw.
Will the PF80S10FPY01 fit in my space?
76.375" tall, 27" wide, 27" deep. Measure your space including clearances before ordering.
What electrical circuit does the PF80S10FPY01 need?
120V, 15A dedicated circuit. Check your electrical panel before installation.
Does the PF80S10FPY01 work in cold climates?
The heat pump operates down to 35°F ambient temperature. Below that, it switches to standard electric resistance mode, losing the efficiency advantage. In cold climates, install inside the heated building envelope, not in an unheated garage.
What warranty does the PF80S10FPY01 come with?
10-year tank warranty, 10-year parts. Register with GE Profile after installation to activate full coverage.
Is the PF80S10FPY01 eligible for rebates?
ENERGY STAR certified heat pump water heater. The federal tax credit (IRA Section 25C, up to $2,000) expired December 31, 2025. State and utility rebates may still apply depending on your location.
Is this unit future-proof under the 2029 DOE standards?
Yes. Starting May 2029, electric water heaters over 35 gallons must use heat pump technology. This unit already exceeds that standard.
Full specifications
| Performance |
| UEF | 3.5 |
|---|
| First Hour Rating | 94 gal |
|---|
| kW Input | 0.9 kW |
|---|
| Draw Pattern | High |
|---|
| Est. Annual Energy | 1417 kWh/yr |
|---|
| Capacity |
| Storage Volume | 80 gal |
|---|
| Physical |
| Height | 76.375 in |
|---|
| Width | 27 in |
|---|
| Depth | 27 in |
|---|
| Weight | 331 lbs |
|---|
| Connections | 3/4 inch NPT |
|---|
| Electrical |
| Voltage | 120 V |
|---|
| Amperage | 7.5 A |
|---|
| Breaker | 15A dedicated |
|---|
| Heat Pump |
| Type | 120 Volt Integrated HPWH |
|---|
| Min Ambient | 35 °F |
|---|
| Refrigerant | R1234YF |
|---|
| Sound Level | 41 dBA |
|---|
| Warranty |
| Tank | 10 yr |
|---|
| Parts | 10 yr |
|---|
| Labor | 1 yr |
|---|
| Certifications |
| ENERGY STAR | Certified |
|---|
| Markets | United States |
Keep the route moving
Other GE Profile models and the full heat pump guide, if this one isn't the right fit.
Sources. ENERGY STAR, Retailer listing. Specs last verified 2026-11-01.
Methodology
As an Amazon Associate we earn from qualifying purchases. RatingPlate may earn a commission when you use qualifying Amazon links. Links to Amazon are marked "(paid link)". We never display prices because Amazon prohibits showing prices outside their platform.