Sizing guideCapacity, first-hour rating, and temperature-rise fit.Accessories hubInstall extras, code-adjacent parts, and paid-link accessory picks.Rating plate guideFind and decode the label on your water heater.Tax credits & rebatesFederal 25C expired. State HEAR status and active rebate programs.Heat pump vs electric tankAnnual cost comparison using verified model specs.Heat pump vs gas tanklessOperating cost, install complexity, and 10-year ownership compared.Replacement cost guideEquipment, labor, and hidden costs by type. 2026 data.Gas to heat pumpReplacing a gas water heater in 2026: costs and rebates.Heat pump vs gas tankOperating cost in all 50 states and DC.Garage and basement installsENERGY STAR certified models compared.Quietest models (dBA)ENERGY STAR certified models compared.DOE 2029 standardsWhat changes in 2029 and which product classes move first.
Home / Guides / Quietest Heat Pump Water Heaters
Guide

Quietest Heat Pump Water Heaters by Rated dBA

Rated sound levels from ENERGY STAR certification data, and what they mean in a real house.

Short answer (updated November 1, 2026)

Rated sound levels for heat pump water heaters range from 37 to 55 dBA in ENERGY STAR data. The quietest rated model is the SANCO2 GS5-45HPC HP + ECO-43SSAQB at 37 dBA; the quietest all-in-one (integrated) unit is the GE Profile PF40S10FPY01 at 41 dBA. For scale, 40 dBA is a quiet library and 50 dBA is a quiet conversation. Only 159 of 726 certified listings report a sound level, so many popular models are not in this table.

Every model with a rated sound level, quietest first

Split systems place the compressor outdoors, so indoor noise is lower than the rating suggests. Variants with identical certified performance are grouped.

ModelTypeGallonsNoiseUEFkWh/yrMin. air temp
SANCO2 GS5-45HPC HP + ECO-43SSAQB
+ 1 variant
Split4337 dBA3.70868—
SANCO2 GS5-45HPC HP + ECO-83SSAQB
+ 1 variant
Split8337 dBA3.801,313-26°F
SANCO2 GS5-45HPC HP + ECO-119GLBK
+ 1 variant
Split11937 dBA3.721,333-26°F
GE Profile PF40S10FPY01
+ 1 variant
120V plug-in4041 dBA3.1072435°F
GE Profile PH40S10BPY01240V4041 dBA4.2077335°F
GE Profile PK50S10FNY01240V5041 dBA4.2077335°F
GE Profile PK65S10FNY01240V6541 dBA4.1079235°F
GE Profile PF50S10FPY01 (no longer made)
+ 1 variant
120V plug-in5041 dBA3.201,01535°F
GE Profile PH50S10BNY01240V5041 dBA4.501,10235°F
GE Profile PH80S10BNY01240V8041 dBA4.501,10235°F
GE Profile PK80S10FNY01240V8041 dBA4.501,10235°F
GE Profile PH80S10BPY01 (no longer made)240V8041 dBA4.401,12735°F
GE Profile PH50S10BPY01 (no longer made)240V5041 dBA4.301,15435°F
GE Profile PH65S10BNY01240V6541 dBA4.301,15435°F
GE Profile PH65S10BPY01 (no longer made)240V6541 dBA4.301,15435°F
GE Profile PF80S10FPY01 (no longer made)
+ 1 variant
120V plug-in8041 dBA3.501,41735°F
GE Profile PF65S10FPY01 (no longer made)
+ 1 variant
120V plug-in6541 dBA3.401,45935°F
LG APHWC501M240V5342 dBA3.931,26223°F
LG APHWC801M240V7242 dBA3.901,27223°F
A. O. Smith HPTS-50-2240V4645 dBA3.8083137°F
Navien NWP500S050AUMB240V4445 dBA3.8584041°F
American HPA10250H045DV-2240V4645 dBA3.6888337°F
A. O. Smith HPTS-66-2240V6745 dBA3.701,23337°F
Navien NWP500S065AUMB240V6145 dBA4.031,24541°F
Navien NWP500S080AUMB240V7445 dBA4.051,26541°F
A. O. Smith HPTS-80-2240V8245 dBA3.881,27937°F
American HPA10280H045DV-2240V8145 dBA3.881,27937°F
American HPA10266H045DV-2240V6845 dBA3.841,29237°F
A. O. Smith HPTV-50-2
+ 5 variants incl. American, Lochinvar, RELIANCE WATER HEATERS
120V plug-in4645 dBA3.001,55037°F
A. O. Smith HPTV-66-2
+ 5 variants incl. American, Lochinvar, RELIANCE WATER HEATERS
120V plug-in6845 dBA3.201,55037°F
A. O. Smith HPTV-80-2
+ 5 variants incl. American, Lochinvar, RELIANCE WATER HEATERS
120V plug-in8245 dBA3.001,65437°F
Eco-Logical OMNI-50HP1-1ASplit4649 dBA3.306815°F
Eco-Logical OMNI-50HP2-1ASplit4649 dBA4.237695°F
Rinnai REHP50C
+ 1 variant
240V4649 dBA3.7584437.4°F
Rheem PROPH50 T2 RH400-30240V4549 dBA3.8884637°F
1HVAC ACIQ-50G-HP-WH
+ 4 variants incl. ACIQ, DIYCOOL, PolarWave
240V4749 dBA3.7585537.4°F
Alsetria HPWH-50G
+ 1 variant incl. ECO-AIR
240V4749 dBA3.7585537.4°F
Bosch TR7000T - 50CA
+ 1 variant
240V4749 dBA3.7585537.4°F
Custom Comfort CCOHPWH50A240V4749 dBA3.7585537.4°F
Eco-Logical ECO-50HPM1A240V4749 dBA3.7585537.4°F
Perfect aire 1PAWH50G
+ 1 variant incl. Gridless
240V4749 dBA3.7585537.4°F
Kepler AZMCHW-50VN3A240V4749 dBA3.7585537.4°F
Midea MAWH50D2AKH
+ 3 variants
240V4749 dBA3.7585537.4°F
NOVAIR TCL-50GL-R134A240V4749 dBA3.7585537.4°F
Senville SENWH-HP50
+ 1 variant
240V4749 dBA3.7585537.4°F
stream33 S33-HPWH50240V4749 dBA3.7585537.4°F
Rheem PROPH40 T2 RH400-30240V3649 dBA3.8385937°F
A. O. Smith HPTA-50-2240V4649 dBA3.6888337°F
A. O. Smith HPTA-40-2240V3649 dBA3.6090237°F
Rheem PROPH65 T2 RH400-30240V5949 dBA4.051,18437°F
Eco-Logical OMNI-80HP2-1ASplit7449 dBA4.111,2065°F
Rheem PROPH80 T2 RH400-30240V7249 dBA4.071,21337°F
Rinnai REHP80
+ 2 variants
240V7549 dBA4.001,22537.4°F
1HVAC ACIQ-80G-HP-WH
+ 4 variants incl. ACIQ, DIYCOOL, PolarWave
240V7449 dBA4.001,24037.4°F
Alsetria HPWH - 65G
+ 1 variant incl. ECO-AIR
240V6049 dBA3.901,24037.4°F
Alsetria HPWH-80G
+ 1 variant incl. ECO-AIR
240V7449 dBA4.001,24037.4°F
Bosch TR7000T-65CA
+ 1 variant
240V6049 dBA3.901,24037.4°F
Bosch TR7000T - 80CA
+ 1 variant
240V7449 dBA4.001,24037.4°F
Custom Comfort CCOHPWH65A240V6049 dBA3.901,24037.4°F
Custom Comfort CCOHPWH80A240V7449 dBA4.001,24037.4°F
Eco-Logical ECO-65HPM1A240V6049 dBA3.901,24037.4°F
Eco-Logical ECO-80HPM1A240V7449 dBA4.001,24037.4°F
Gridless AYHW80G240V7449 dBA4.001,24037.4°F
Kepler AZMCHW-65VN3A240V6049 dBA3.901,24037.4°F
Kepler AZMCHW-80VN3A240V7449 dBA4.001,24037.4°F
Midea MAWH65D2AKH
+ 3 variants
240V6049 dBA3.901,24037.4°F
Midea MAWH80D2AKH
+ 3 variants
240V7449 dBA4.001,24037.4°F
NOVAIR TCL-65GL-R134A240V6049 dBA3.901,24037.4°F
NOVAIR TCL-80GL-R134A240V7449 dBA4.001,24037.4°F
Rinnai REHP65
+ 5 variants
240V6049 dBA3.901,24037.4°F
Senville SENWH-HP65
+ 1 variant
240V6049 dBA3.901,24037.4°F
stream33 S33-HPWH80240V7449 dBA4.001,24037.4°F
A. O. Smith HPTA-80-2240V8149 dBA3.881,27937°F
A. O. Smith HPTA-66-2240V6849 dBA3.841,29237°F
Midea MAHW-50VN3A240V4749.5 dBA3.7585537.4°F
Midea MAHW-65VN3A240V6049.5 dBA3.901,24037.4°F
Midea MAHW-80VN3A240V7449.5 dBA4.001,24037.4°F
Bradford White RE2HP50-1NCTT240V4551 dBA3.8983537°F
Bradford White RE2H50S240V4551 dBA3.4494435°F
Bradford White RE2HP65-1NCTT240V6551 dBA4.201,18137°F
Bradford White RE2HP80-1NCTT240V7551 dBA4.001,24037°F
Bradford White RE2H65T240V6451 dBA3.641,36335°F
Bradford White RE2H80T240V7551 dBA3.591,38235°F
Noritz NHP50
+ 3 variants incl. Hubbell, VAUGHN THERMAL
240V4754 dBA3.4693835°F
Noritz NHP65
+ 3 variants incl. Hubbell, VAUGHN THERMAL
240V5754 dBA3.3497435°F
VAUGHN THERMAL MP55FHPT240V5554 dBA3.3098235°F
VAUGHN THERMAL MP80FHPT240V8054 dBA3.501,37535°F
VAUGHN THERMAL MP120FHPT240V11954 dBA3.501,41835°F
Noritz NHP80
+ 3 variants incl. Hubbell, VAUGHN THERMAL
240V7454 dBA3.481,42435°F
Noritz NHP120
+ 3 variants incl. Hubbell, VAUGHN THERMAL
240V10954 dBA3.381,46735°F
Rheem PROPH50 T0 RH120120V plug-in4655 dBA3.001,082—

How loud is a heat pump water heater in practice?

The compressor and fan run for several hours a day, mostly after hot water use. A rating in the low 40s is hard to hear through a closed door; a rating near 50 to 55 dBA is noticeable in an adjacent room. Placement matters as much as the rating: a garage, basement, or utility room with a closed door makes most units unobtrusive, while a closet next to a bedroom is where noise complaints come from. Rubber isolation pads and keeping the unit off a shared wall help.

dBA ratings are measured at a set distance under test conditions. They are useful for comparing models, not for predicting exactly what you will hear.

Keep going

Common questions

What is the quietest heat pump water heater?
By rated sound level in ENERGY STAR data, the SANCO2 GS5-45HPC HP + ECO-43SSAQB at 37 dBA. The quietest integrated (all-in-one) model is the GE Profile PF40S10FPY01 at 41 dBA.
Are heat pump water heaters loud?
Rated levels run 37 to 55 dBA, comparable to a refrigerator up to a quiet conversation. Most people do not notice one in a garage or basement.
Can I put a heat pump water heater in a closet?
Only if the closet meets the manufacturer's air volume requirement (often about 700 cubic feet) or uses a louvered door or ducting kit. Noise is more noticeable in a closet near living space.